Symmetric Hann taper audit
Apply a Hann taper and document its gain and endpoint convention.
Your entries stay in this page’s memory and are not submitted to us. Downloads are generated locally. Reloading or leaving the page clears your entries. Do not enter patient information.
Use comma-separated finite numbers on one line. Magnitudes must be at most 1e9 and at least 1e-12, or zero.
The starting values are hypothetical. Results update as you edit. Use aggregate or synthetic inputs only.
Calculation results
- Window weights
- 0, 0.75, 0.75, 0
- Tapered sequence
- 0, 1.5, 1.5, 0
- Coherent gain
- 0.375
- Sum of squared weights
- 1.125
How to interpret the output
Uses the symmetric Hann convention w[n]=0.5−0.5 cos(2πn/(N−1)), not the periodic convention. Reports taper weights, weighted observations, mean weight (coherent gain) and sum of squared weights. These quantities support a scaling audit; there is no universal amplitude or power correction. Original observations are not changed. Source checked 15 November 2026.
Method reference